Defect and task list
RBC/IL
Start signal is indicated gray when locked in route over trailing but unsupervised point. Should be shown red.
Start signal of route over unsupervised point cannot be manually released. Only destination signal is released
RBCIL can apparently give MA without locked route
Restablish JPs function to invalidate position when train is located after trailing point.
Implement determination of train at stopping location in rear of signal.
If train is moved back in SR, the previous MA is still valid and the train will run accordingly when set to ATO
Any “old” MA to be cleared when train leaves mode ATO or FS.
Send void MA to all trains when RBCIL is initialized.
ARS disabled is not preventing automatic route setting if the signal is a via signal in a route
HMI
OBU
Auto detection of nominel driving direction is prone to power supply jitter. Filter mechanism to be implemented.
MA is not cleared when train is near EOA
Any “old” MA to be cleared when train leaves mode ATO or FS.