Defect and task list

RBC/IL

  • Start signal is indicated gray when locked in route over trailing but unsupervised point. Should be shown red.
  • Start signal of route over unsupervised point cannot be manually released. Only destination signal is released
  • RBCIL can apparently give MA without locked route
  • Restablish JPs function to invalidate position when train is located after trailing point.
  • Implement determination of train at stopping location in rear of signal.
  • If train is moved back in SR, the previous MA is still valid and the train will run accordingly when set to ATO
  • Any “old” MA to be cleared when train leaves mode ATO or FS.
  • Send void MA to all trains when RBCIL is initialized.
  • ARS disabled is not preventing automatic route setting if the signal is a via signal in a route

HMI

OBU

  • Auto detection of nominel driving direction is prone to power supply jitter. Filter mechanism to be implemented.