Table of Contents

Defect and task list

RBC/IL

  • Start signal is indicated gray when locked in route over trailing but unsupervised point. Should be shown red.
  • Start signal of route over unsupervised point cannot be manually released. Only destination signal is released
  • RBCIL can apparently give MA without locked route
  • Restablish JPs function to invalidate position when train is located after trailing point.
  • Implement determination of train at stopping location in rear of signal.
  • If train is moved back in SR, the previous MA is still valid and the train will run accordingly when set to ATO

HMI

  • Signals are shown in stop when not locked in route (checked with model data). Should be grey.

OBU

  • Auto detection of nominel driving direction is prone to power supply jitter. Filter mechanism to be implemented.